- Wide range input voltage
- Short transfer time
- 3 steps AVR system
- Intelligent battery management
- Battery low voltage automatic shutdown
- Over-voltage and under-voltage protection
INPUT | |
---|---|
Voltage Range | 145V~290V |
Frequency | 60Hz+-0.5 |
OUTPUT | |
Voltage (on battery) | Simulated sine wave at 205V~235V |
AVR | AVR automatically increase output voltage 15% above input voltage, if-9% to 25% of nominal. AVR decrease output voltage 15% below input voltage if +9% to 25% of nominal |
Transfer Time | <10ms |
PHYSICAL | |
Net Weight (kg) | 12.0kg |
Gross Weight (kg) | 12.5kg |
BATTERY | |
Type | Sealed, maintenance-free lead acid |
Typical Recharge Time | 10-12 hours |
Protection | Automatic self-test & discharge protection, replace battery indicator |
ALARM | |
Backup Time | 3-20 minutes (depending on computer load) |
Battery Backup | Slow beeping sound (once per 8 seconds) |
Battery Low | Rapid beeping sound (once per 0.5 second) |
Overload | Continuous beeping sound |
ENVIRONMENT | |
Ambient Operation | 3500 meters max. Elevation, 0-95% humidity non-condensing, 0-40°C |
Audible Noise | <40dBA (1 meter form surface) |
Storage condition | 1500 meters max. |
- Wide range input voltage
- Short transfer time
- 3 steps AVR system
- Intelligent battery management
- Battery low voltage automatic shutdown
- Over-voltage and under-voltage protection
Input voltage | 145VAC~290VAC |
---|---|
Output voltage | 195VAC~255VAC |
Output wave form | Stepped wave during the b/up mode |
Output frequency | 60Hz |
Battery rating | 12V/9Ah |
Backup time | 3-20 minutes |
Noise level | Less than 45dB |
Operating temperature | 0-45 deg C |
Humidity | 10 to 90% non condensing |
Weight | 7kg |
- Built-in voltage regulator
- DVR friendly power supply
- Super fast charging
- Charging time 2-4 hours
- Quick automatic backup & charging operation
- Overload protection
Capacity | 650VA / 390W |
---|---|
Input | |
Nominal voltage | 220V |
Input voltage range | 140~300V |
Output | |
Nominal voltage | 220V |
Voltage regulation (bat. mode) | +/-10% |
Frequency | 60Hz |
Frequency regulation (bat. mode) | +/-1 Hz |
Output waveform | Stepped sine wave |
Battery | |
Battery type | (1)12V 7Ah |
Recharge time | 2-4 hours to 90% after complete discharge |
Transfer time | |
Typical | 10 ms typical |
Indicator | |
AC mode | Green lighting |
Battery mode | Green flashing |
Audible alarm | |
Backup mode | Sounding every 10 seconds |
Low battery | Sounding every 1 seconds |
Overload | Sounding every 0.5 seconds |
Fault | Continuously sounding |
Protection | |
Full protection | Discharge. overcharge and overload protection |
Physical | |
Dimensions H*W*D | 143*100*278 |
Weight | |
Net weight | 4.2kg |
Environment | |
Operating environment | 0°C~40°C |
Noise Level | less than 40dB |
Elevation | <2000m |
Back up time | |
For a 100W load | 16min |
- High frequency and double converstion online
- Fully digitized mircoprocessor control
- Wide input voltage range
- LCD display
- Advance battery management
- Cold start
- Automatic battery charging in UPS off mode
- Lighting and surge protection
Model number | MF6KVA |
Capacity | 3000V |
Rating input voltage | 230V |
Operating voltage range | 170V-280V |
Input power factor | ≥99% |
Norminal output voltage | 230V |
Output frequency | sychronized with the utility on AC mode, 50HZ/60HZ±0.2% on battery mode |
Harmonic distortion | <2%(liner load) |
Efficiency | ≥90% |
Battery specification | |
Battery DC voltage | 240VDC |
Battery type | 12/7AH*20 |
Back up time(50% load) | 20min |
Back up time(full load) | 7min |
Charge current(Standard unit) | 1A |
Typical recharge time | 6-8hours(to 90% of full capacity) |
Transfer time(Between AC mode and battery mode) | 0ms |
Transfer time(Between AC mode and bypass mode) | 0ms |
Operating temperature | 0-40° |
Noise level | <45dB |